Check that the flow switch is plugged into the connector on the bottom of the control unit and that the wire is not cut or damaged.
Aqua rite chlorine generator no lights.
Make sure you have at least 12 of straight.
I have a aqua rite chlorine generator that i installed about 4 years ago.
This also means that chlorine production has stopped.
I have kept it clean and serviced it at the proper intervals so this is a surprise.
I checked yesterday and i have no lights at all no digital display.
It is hooked to a 2 speed pump and is supposed to be on and generating when the pump is on low speed most of the day.
If the incorrect cell is chosen the salt level amperage and voltage will not be correct and the system will turn the chlorinator off.
Cell voltage 12 8.
When these leds are on the salt level is 2300 ppm or below.
No flow led illuminated.
The aquarite has no lights on meaning power led light and generating lights are off although it is showing the salt count to be 3200.
Hello chris thank you for contacting inyo.
When looking online at the goldline manual i see that after 10 04 it has a different 20 amp fuse.
Before operation the aqua rite must be configured for the chlorinator cell that will be used.
Inspect cell led will flash alone when the 500 operational hour timer has expired.
Check that the flow switch is plugged into the connector on the bottom of the control unit and that the wire is not cut or damaged.
Salt display shows continuous 3700 and the cell is cle read more.
No power generator or flow indicator lights.
A simple fix as you can see if you know.
I have pulled the cover to look at the circuit board but i m not sure what i am looking for.
T 1 5 is the factory default.
I have a 2 year old aqua rite generator t 15 cell type.
Cell current 0 amps.
I do not see a twist out fuse.
Check out pages 31 34 of the aquarite troubleshooting manual there is a detailed flow chart that will help diagnose the problem.
The aqua rite has sensed a no flow condition and has stopped generating chlorine.
Make sure you have at least 12 of straight pipe before the flow switch.